Comparison of AC/A Ratio in True and Simulated Divergence Excess Exotropia

http://doi.org/10.36351/pjo.v37i2.1192

Authors

  • Sana Sagheer Punjab Rangers Teaching Hospital/Rahbar Medical & Dental College, Lahore
  • Muhammad Ali Haider Punjab Rangers Teaching Hospital/Rahbar Medical & Dental College, Lahore
  • Attaullah Shah Bukhari Khairpur Medical college, Khairpur Mirs
  • Uzma Sattar Punjab Rangers Teaching Hospital/Rahbar Medical & Dental College, Lahore
  • Iftikhar Ahmed Punjab Rangers Teaching Hospital/Rahbar Medical & Dental College, Lahore

DOI:

https://doi.org/10.36351/pjo.v37i2.1192

Keywords:

Intermittent exotropia, True simulated divergence excess exotropia, simulated divergence excess exotropia.

Abstract

Purpose:  To compare the accommodation convergence per accommodation ratio (AC/A) in true and simulated divergence excess exotropia.

Study Design:  Comparative cross sectional study.

Place and Duration of Study:  Department of ophthalmology, Punjab Rangers teaching hospital, Lahore, from July 2019 to December 2019.

Methods:  The study included 20 patients each of intermittent exotropia (XT) true and simulated divergence excess exotropia (XT).All the subjects underwent complete orthoptic assessmentthat included AC/A ratio calculation through heterophoria method after monocular occlusion.

Results:  The Results showed that patients with true divergence excess exotropia have a high AC/A ratio as compared to patients with simulated divergence excess exotropia who have a normal AC/A ratio. 57% patients showed true divergence excess exotropia with high AC/A ratio while 43% had divergence excess with normal AC/A ratio.

Conclusion:  The response of AC/A was found to be higher in patients with true divergence excess exotropia after monocular occlusion.

Key Words:  Intermittent exotropia, True simulated divergence excess exotropia, simulated divergence excess exotropia.

Downloads

Published

22-01-2021

How to Cite

1.
Sagheer S, Haider MA, Bukhari AS, Sattar U, Ahmed I. Comparison of AC/A Ratio in True and Simulated Divergence Excess Exotropia: http://doi.org/10.36351/pjo.v37i2.1192. pak J Ophthalmol [Internet]. 2021 Jan. 22 [cited 2024 Apr. 20];37(2). Available from: https://pjo.org.pk/index.php/pjo/article/view/1192